1/2″ Air Heliax Plenum Air Dielectric 50 Ohm Coax White Cable Per Foot

$4.06

Availability: In stock

Description

This is a half inch thick diameter Heliax Plenum Air Dielectric coaxial cable. It has off-white color. It has 50 Ohm impedance. It is sold by the foot. It is manufactured by Andrew antenna & wire company that is now owned by CommScope communication infrastructure company. Item name: HELIAX Plenum Rated Air Dielectric Coaxial Cable, corrugated aluminum, 1/2 inch, off-white color PVC jacket. SKU: AL4RPV-50.

These frequency signal transmitting coax cables are used in systems such as cell phone signal booster, repeater, distributed antenna system (DAS), bidirectional amplifier (BDA) systems, etc. to connect antennas with system components such as cellular amplifier main base unit. Prep tool and cable connector(s) not included with purchase. They must be purchased separately, as needed.


Please Note: This half an inch thick coax. cable is available in bulk and is priced per foot because it is sold by the foot. Therefore, after adding this item to cart, please update “quantity” in shopping cart based upon number of feet required.


GENERAL SPECIFICATIONS:

Flexibility

Standard.

Jacket Color

Off-white.


DIMENSIONS:

Diameter Over Jacket

15.748 mm | 0.62 in.

Inner Conductor OD

4.572 mm | 0.18 in.

Outer Conductor OD

14.046 mm | 0.553 in.

Nominal Size

1/2 inch.


ELECTRICAL SPECIFICATIONS:

Cable Impedance

50 ohm ±1 ohm.

Capacitance

75.459 pF/m | 23 pF/ft.

dc Resistance, Inner Conductor

0.48 ohms/kft | 1.575 ohms/km.

dc Resistance, Outer Conductor

0.48 ohms/kft | 1.575 ohms/km.

dc Test Voltage

4000 V.

Inductance

0.19 µH/m | 0.058 µH/ft.

Insulation Resistance

100000 MOhms-km.

Jacket Spark Test Voltage (rms)

5000 V.

Operating Frequency Band

1 – 6000 MHz.

Peak Power

40 kW.

Power Attenuation

2.325000047683716.

Pulse Reflection

0.5%.

Velocity

88 %.


ATTENUATION:

Frequency 1 MHz

Attenuation (dB/100 ft) = 0.066; Average Power (kW) = 35.37.

Frequency 1.5 MHz

Attenuation (dB/100 ft) = 0.081; Average Power (kW) = 28.84.

Frequency 2 MHz

Attenuation (dB/100 ft) = 0.093; Average Power (kW) = 24.95.

Frequency 10 MHz

Attenuation (dB/100 ft) = 0.211; Average Power (kW) = 11.04.

Frequency 20 MHz

Attenuation (dB/100 ft) = 0.300; Average Power (kW) = 7.75.

Frequency 30 MHz

Attenuation (dB/100 ft) = 0.370; Average Power (kW) = 6.29.

Frequency 50 MHz

Attenuation (dB/100 ft) = 0.482; Average Power (kW) = 4.83.

Frequency 85 MHz

Attenuation (dB/100 ft) = 0.636; Average Power (kW) = 3.66

Frequency 88 MHz

Attenuation (dB/100 ft) = 0.648; Average Power (kW) = 3.59.

Frequency 100 MHz

Attenuation (dB/100 ft) = 0.693; Average Power (kW) = 3.35.

Frequency 108 MHz

Attenuation (dB/100 ft) = 0.722; Average Power (kW) = 3.22.

Frequency 150 MHz

Attenuation (dB/100 ft) = 0.860; Average Power (kW) = 2.70.

Frequency 174 MHz

Attenuation (dB/100 ft) = 0.931; Average Power (kW) = 2.50.

Frequency 200 MHz

Attenuation (dB/100 ft) = 1.003; Average Power (kW) = 2.32.

Frequency 204 MHz

Attenuation (dB/100 ft) = 1.014; Average Power (kW) = 2.29.

Frequency 300 MHz

Attenuation (dB/100 ft) = 1.251; Average Power (kW) = 1.86.

Frequency 400 MHz

Attenuation (dB/100 ft) = 1.465; Average Power (kW) = 1.59.

Frequency 450 MHz

Attenuation (dB/100 ft) = 1.565; Average Power (kW) = 1.49.

Frequency 460 MHz

Attenuation (dB/100 ft) = 1.584; Average Power (kW) = 1.47.

Frequency 500 MHz

Attenuation (dB/100 ft) = 1.659; Average Power (kW) = 1.40.

Frequency 512 MHz

Attenuation (dB/100 ft) = 1.682; Average Power (kW) = 1.38.

Frequency 600 MHz

Attenuation (dB/100 ft) = 1.839; Average Power (kW) = 1.26.

Frequency 700 MHz

Attenuation (dB/100 ft) = 2.007; Average Power (kW) = 1.16.

Frequency 800 MHz

Attenuation (dB/100 ft) = 2.166; Average Power (kW) = 1.07.

Frequency 824 MHz

Attenuation (dB/100 ft) = 2.203; Average Power (kW) = 1.06.

Frequency 894 MHz

Attenuation (dB/100 ft) = 2.308; Average Power (kW) = 1.01.

Frequency 960 MHz

Attenuation (dB/100 ft) = 2.405; Average Power (kW) = 0.97.

Frequency 1000 MHz

Attenuation (dB/100 ft) = 2.463; Average Power (kW) = 0.94.

Frequency 1218 MHz

Attenuation (dB/100 ft) = 2.764; Average Power (kW) = 0.84.

Frequency 1250 MHz

Attenuation (dB/100 ft) = 2.806; Average Power (kW) = 0.83.

Frequency 1500 MHz

Attenuation (dB/100 ft) = 3.126; Average Power (kW) = 0.74.

Frequency 1700 MHz

Attenuation (dB/100 ft) = 3.369; Average Power (kW) = 0.69.

Frequency 1794 MHz

Attenuation (dB/100 ft) = 3.480; Average Power (kW) = 0.67.

Frequency 1800.0 MHz

Attenuation (dB/100 ft) = 3.487; Average Power (kW) = 0.67.

Frequency 2000 MHz

Attenuation (dB/100 ft) = 3.716; Average Power (kW) = 0.63.

Frequency 2100 MHz

Attenuation (dB/100 ft) = 3.828; Average Power (kW) = 0.61.

Frequency 2200 MHz

Attenuation (dB/100 ft) = 3.938; Average Power (kW) = 0.59.

Frequency 2300 MHz

Attenuation (dB/100 ft) = 4.046; Average Power (kW) = 0.57.

Frequency 2500 MHz

Attenuation (dB/100 ft) = 4.259; Average Power (kW) = 0.55.

Frequency 2700 MHz

Attenuation (dB/100 ft) = 4.467; Average Power (kW) = 0.52.

Frequency 3000 MHz

Attenuation (dB/100 ft) = 4.770; Average Power (kW) = 0.49.

Frequency 3400 MHz

Attenuation (dB/100 ft) = 5.159; Average Power (kW) = 0.45.

Frequency 3600 MHz

Attenuation (dB/100 ft) = 5.349; Average Power (kW) = 0.43.

Frequency 3700 MHz

Attenuation (dB/100 ft) = 5.443; Average Power (kW) = 0.43.

Frequency 3800 MHz

Attenuation (dB/100 ft) = 5.536; Average Power (kW) = 0.42.

Frequency 3900 MHz

Attenuation (dB/100 ft) = 5.628; Average Power (kW) = 0.41.

Frequency 4000 MHz

Attenuation (dB/100 ft) = 5.720; Average Power (kW) = 0.41.

Frequency 4100 MHz

Attenuation (dB/100 ft) = 5.811; Average Power (kW) = 0.40.

Frequency 4200 MHz

Attenuation (dB/100 ft) = 5.902; Average Power (kW) = 0.39.

Frequency 4300 MHz

Attenuation (dB/100 ft) = 5.991; Average Power (kW) = 0.39.

Frequency 4400 MHz

Attenuation (dB/100 ft) = 6.081; Average Power (kW) = 0.38.

Frequency 4500 MHz

Attenuation (dB/100 ft) = 6.169; Average Power (kW) = 0.38.

Frequency 4600 MHz

Attenuation (dB/100 ft) = 6.257; Average Power (kW) = 0.37.

Frequency 4700 MHz

Attenuation (dB/100 ft) = 6.345; Average Power (kW) = 0.37.

Frequency 4800 MHz

Attenuation (dB/100 ft) = 6.432; Average Power (kW) = 0.36.

Frequency 4900 MHz

Attenuation (dB/100 ft) = 6.519; Average Power (kW) = 0.36.

Frequency 5000 MHz

Attenuation (dB/100 ft) = 6.605; Average Power (kW) = 0.35.

Frequency 6000 MHz

Attenuation (dB/100 ft) = 7.443; Average Power (kW) = 0.31.


RETURN LOSS & VSWR:

Frequency Band 700–894 MHz

VSWR = 1.25; Return Loss (dB) = 19.10

Frequency Band 806–960 MHz

VSWR = 1.25; Return Loss (dB) = 19.10

Frequency Band 1700–2200 MHz

VSWR = 1.25; Return Loss (dB) = 19.10


MATERIAL SPECIFICATIONS:

Dielectric Material

PE spline.

Jacket Material

PVC.

Inner Conductor Material

Copper-clad aluminum wire.

Outer Conductor Material

Corrugated aluminum.


MECHANICAL SPECIFICATIONS:

Minimum Bend Radius, multiple Bends

127 mm | 5 in.

Minimum Bend Radius, Single Bend

63.5 mm | 2.5 in.

Number of Bends, minimum

15.

Tensile Strength

79 kg | 174.165 lb.

Bending Moment

6.779 N-m | 5 ft lb.

Flat Plate Crush Strength

1.429 kg/mm | 80 lb/in.


ENVIRONMENTAL SPECIFICATIONS:

Installation temperature

-5 °C to +60 °C (+23 °F to +140 °F).

Operating Temperature

-20 °C to +85 °C (-4 °F to +185 °F).

Storage Temperature

-20 °C to +85 °C (-4 °F to +185 °F).

Attenuation, Ambient Temperature

20 °C | 68 °F.

Average Power, Ambient Temperature

40 °C | 104 °F.

Average Power, Inner Conductor Temperature

100 °C | 212 °F.

Fire Retardancy Test Method

NFPA 262/CATVP/CMP.


PACKAGING AND WEIGHTS:

Cable weight

0.208 kg/m | 0.14 lb/ft.


REGULATORY COMPLIANCE/CERTIFICATIONS:

c(ETL)us Certification

CATVP/CMP.

ETL Certification

CATVP/CMP.

ISO 9001:2015

Designed, manufactured and/or distributed under this quality management system.


Additional information

Color

Black, Blue, Green, Indigo, Light-Blue, Red

Size

Extra Large, Large, Medium, Small

Brand

Adidas

Reviews

There are no reviews yet.


Be the first to review “1/2″ Air Heliax Plenum Air Dielectric 50 Ohm Coax White Cable Per Foot”